| Work Zone II Master Unit | |
| GPM | 0.5 |
| PSI | 1,000 |
| Fan | 30'' High-Composite |
| Height | Telescopes from 59'' to 70'' |
| CFM | 12,000 |
| Filtration | 10 and 5 Micron |
| Solenoid | Sealed Inlet Water |
| Clearing | Stainless Steel Drain Ball Valve |
| Safety | Integrated Inlet Water Low Pressure Cutoff Switch |
| Connections | Solid Brass Male/Female Q/Ds (No tools required) |
| Stages | 2 stages with option of running only one stage |
| HP/ Pump mtr | 0.5 |
| HP/ Fan | 0.5 |
| Pump Motor | Totally Enclosed Fan Cooled (TEFC Certified) |
| Fan Motor | Fixed Mount/ Non Oscillating |
| Controls | Industrial Grade 2 Position On/Off Switch |
| Power | Available in both 115V/60HZ or 220V/50HZ |
| Supports | One Satellite |
| Work Zone II Plus Master Unit | |
| GPM | 1.1 |
| PSI | 1,000 |
| Fan | 30'' High-Composite |
| Height | Telescopes from 59'' to 70'' |
| CFM | 12,000 |
| Filtration | 10 and 5 Micron |
| Solenoid | Sealed Inlet Water |
| Clearing | Stainless Steel Drain Ball Valve |
| Safety | Integrated Inlet Water Low Pressure Cutoff Switch |
| Connections | Solid Brass Male/Female Q/Ds (No tools required) |
| Stages | 2 stages with option of running only one stage |
| HP/ Pump mtr | 1 |
| HP/ Fan | 0.5 |
| Pump Motor | Totally Enclosed Fan Cooled (TEFC Certified) |
| Fan Motor | Fixed Mount/ Non Oscillating |
| Controls | Industrial Grade 2 Position On/Off Switch |
| Power | Available in both 115V/60HZ or 220V/50HZ |
| Supports | Up to 4 Satellites |
| Work Zone III Master Unit | |
| GPM | 1.1 |
| PSI | 1,000 |
| Fan | 30'' High-Composite |
| Height | Telescopes from 59'' to 70'' |
| CFM | 12,000 |
| Filtration | 10 and 5 Micron |
| Solenoid | Sealed Inlet Water |
| Clearing | Stainless Steel Drain Ball Valve |
| Safety | Integrated Inlet Water Low Pressure Cutoff Switch |
| Connections | Solid Brass Male/Female Q/Ds (No tools required) |
| Stages | 3 stages with option of running on 1, 2, or 3 stages |
| HP/ Pump mtr | 1 |
| HP/ Fan | 0.5 |
| Pump Motor | Totally Enclosed Fan Cooled (TEFC Certified) |
| Fan Motor | Fixed Mount/ Non Oscillating |
| Controls | Industrial Grade 2 Position On/Off Switch |
| Power | Available in both 115V/60HZ or 220V/50HZ |
| Supports | Up to 4 Satellites |
| Work Zone IV Master Unit | |
| GPM | 0.5 |
| PSI | 1,000 |
| Fan | 30'' High-Composite |
| Height | Telescopes from 59'' to 70'' |
| CFM | 17,000 |
| Filtration | 10 and 5 Micron |
| Solenoid | Sealed Inlet Water |
| Clearing | Stainless Steel Drain Ball Valve |
| Safety | Integrated Inlet Water Low Pressure Cutoff Switch |
| Connections | N/A |
| Stages | 3 stages with option of running on 1, 2, or 3 stages |
| HP/ Pump mtr | 0.5 |
| HP/ Fan | 1 |
| Pump Motor | Totally Enclosed Fan Cooled (TEFC Certified) |
| Fan Motor | Fixed Mount/ Non Oscillating |
| Controls | Industrial Grade 2 Position On/Off Switch |
| Power | Available in both 115V/60HZ or 220V/50HZ |
| Supports | N/A |